.\" Copyright (c) 1986 Regents of the University of California. .\" All rights reserved. The Berkeley software License Agreement .\" specifies the terms and conditions for redistribution. .\" .\" @(#)de.4 6.2 (Berkeley) 8/20/87 .\" .TH DE 4 "August 20, 1987" .UC 2 .SH NAME de \- DEC DEUNA 10 Mb/s Ethernet interface .SH SYNOPSIS .ft B .nf /sys/conf/SYSTEM: NDE \fIde_controllers\fP # DEUNA .fi .ft R .SH DESCRIPTION The .I de interface provides access to a 10 Mb/s Ethernet network through a Digital Equipment UNIBUS Network Adapter (DEUNA). .PP Each of the host's network addresses is specified at boot time with an SIOCSIFADDR ioctl. The .I de interface employs the address resolution protocol described in .IR arp (4P) to dynamically map between Internet and Ethernet addresses on the local network. .PP The interface normally tries to use a ``trailer'' encapsulation to minimize copying data on input and output. The use of trailers is negotiated with ARP. This negotiation may be disabled, on a per-interface basis, by setting the IFF_NOTRAILERS flag with an SIOCSIFFLAGS ioctl. .SH DIAGNOSTICS \fBde%d: hardware address %s\fP. This is a normal autoconfiguration message noting the 6 byte physical ethernet address of the adapter. .PP \fBde%d: oerror, flags=%b tdrerr=%b (len=%d)\fP. The hardware indicated an error in transmitting a packet to the cable. The status and error flags are reported. .PP \fBde%d: ierror, flags=%b lenerr=%b (len=%d)\fP. The hardware indicated an error in reading a packet from the cable. The status and error flags are reported. .PP \fBde%d: can't handle af%d\fP. The interface was handed a message with addresses formatted in an unsuitable address family; the packet was dropped. .PP \fBde%d: buffer unavailable\fP. The interface received more packets than it had buffers allocated to receive them. .PP \fBde%d: address change failed, csr0=%b csr1=%b\fP. The interface was unable to reprogram its physical ethernet address. This may happen with very early models of the interface. This facility is used only when the controller is not the first network interface configured for XNS. .PP The following messages indicate a probable hardware error performing the indicated operation during autoconfiguration or initialization. The two control and status registers should indicate the nature of the failure. See the hardware manual for details. .PP \fBde%d: reset failed, csr0=%b csr1=%b\fP. .PP \fBde%d: ppcb failed, csr0=%b csr1=%b\fP. .PP \fBde%d: read addr failed, csr0=%b csr1=%b\fP. .PP \fBde%d: wtring failed, csr0=%b csr1=%b\fP. .PP \fBde%d: wtmode failed, csr0=%b csr1=%b\fP. .SH SEE ALSO intro(4N), inet(4F), arp(4P)